Home >> News >>Industry News >> What equipment is used for mask testing
Details

What equipment is used for mask testing

Original title: Recommendation for a complete set of mask testing equipment


     With the outbreak and continuation of the epidemic, in this fight against the new coronavirus epidemic, we learned from major media that wearing a mask is the most effective way to prevent the spread of the virus. For a time, medical masks became a scarce resource. Because of scarcity, many people have no choice but to use “cotton masks” and “homemade plastic masks” instead of medical masks, thinking that as long as they cover their mouth and nose, they can prevent viruses. As everyone knows, the design and production of medical masks are based on standards, only to meet The standard can be regarded as a mask that can effectively block the spread of the virus.


       So, what standards do medical masks refer to? What are the corresponding mask testing equipment?


      This time, the main reference test standards for domestic mask production are listed as follows:


      GB 19083 Medical protective mask


      GB/T 32610 Daily protective mask


      YY 0469 Medical surgical mask


      YY/T 0969 disposable medical mask


      Therefore, in response to the above standard requirements, Jinan Zhongce Electromechanical Equipment Co., Ltd. provides the following medical mask testing equipment:


      1. Test items of mask particle filtration efficiency



The filtration efficiency of the mask filter material should not be less than 30%GB 19083 Medical protective mask
The filtration efficiency of the mask for non-oily particles should not be less than 30%YY 0469 Medical surgical mask
NoYY/T 0969 disposable medical mask
The filtration efficiency of salty particles and oily particles is divided into three levels: Ⅰ ≥99%, Ⅱ 95%, Ⅲ 90%GB/T 32610 Daily protective mask


The filtration efficiency is divided into three levels according to the standard. One level is the filtration efficiency greater than 95%.


Recommended testing equipment: Zhongce PFT-01 mask particle filtration efficiency tester, this tester is suitable for medical protective masks, medical surgical masks, ordinary medical masks and other particle pass efficiency tests.

   

口罩颗粒过滤效率检测仪

Mask particle filtration efficiency detector

2. Breaking strength and static tensile test items


Breaking strength of the connection point between the mask belt and the mask bodyNot less than 10NGB 19083 Medical protective mask
The breaking strength of the mask belt and the connection between the mask belt and the coverGreater than or equal to 20NGB/T 32610 Daily protective mask
Fastness of exhalation valve cover (10N, 10S)There should be no slippage, fracture, or deformationGB/T 32610 Daily protective mask
Mask band breaking strengthNot less than 10NYY 0469 Medical surgical mask
Mask with static tensionNot less than 10NYY/T 0969 disposable medical mask

Recommended equipment: Zhongce TST-02H mask belt tensile testing machine (professional name is intelligent electronic tensile testing machine) + special test fixture


3. Detection items of mask ventilation resistance and pressure difference


Airflow resistanceThe gas flow rate is 85L/min, and the suction resistance shall not exceed 343.2pa (35mmH2O)GB 19083 Medical protective mask
Inspiratory resistanceLess than or equal to 175pa

GB/T 32610 Daily Protection Type

Exhalation resistanceLess than or equal to 145paGB/T 32610 Daily protective mask
Pressure differenceNot more than 49paYY 0469 Medical surgical mask
Ventilation resistanceNot more than 49pa/cm2YY/T 0969 disposable medical mask


Related equipment: Zhongce TQD-02 mask ventilation resistance and pressure difference detector is used to measure the ventilation resistance and pressure difference of masks under specified conditions.

口罩通气阻力及压力差检测仪

Mask ventilation resistance and pressure difference detector

The public test TQD-03 mask airflow resistance and breathing resistance tester is used to measure the inhalation and exhalation resistance of masks under specified conditions. It can also be used to determine the air penetration resistance of textiles, cotton wool, space cotton, masks, etc.

 口罩气流阻力及呼吸阻力试验仪

Mask airflow resistance and breathing resistance tester

4. Mask synthetic blood penetration test items


The synthetic blood is sprayed onto the mask sample at a pressure of 160mmHg, and there should be no penetration inside the mask

GB 19083 Medical protective mask
After 2ml of synthetic blood is sprayed on the outside of the mask at a pressure of 16.0kpa (120mmHg), there should be no penetration on the inside of the mask.YY 0469 Medical surgical mask
NoYY/T 0969 disposable medical mask
NoGB/T 32610 Daily protective mask

Recommended equipment: Public test BPT-01 mask synthetic blood penetration tester is used to test the filtration efficiency of daily protective masks, medical masks, and respirators on particulate matter

口罩合成血液穿透测试仪

Mask synthetic blood penetration tester

Five, mask flame retardant performance test items

   

The materials used should not be flammable, and the burning should not exceed 5s after being removed from the flame

GB 19083 Medical protective mask
The materials used should be non-flammable materials, and the mask burns no more than 5s after leaving the flameYY 0469 Medical surgical mask
NoYY/T 0969 disposable medical mask
NoGB/T 32610 Daily protective mask

Recommended equipment: Zhongce FRT-01 mask flame retardant performance tester is suitable for the determination of the flame retardant performance of medical masks and all protective masks.

口罩阻燃性能测试仪

Mask flame retardant performance tester

6. Test items for mask suitability GB19083-2010 Medical protective masks:


The Medical Mask Fit Tester MFT-01 is used to test the suitability of daily protective masks and medical masks.


   口罩密合度测试仪

Mask Fit Tester

7. Test items for the protective performance of mask particles

GB/T 32610 Daily protective mask

5.5.1 The protective effect requirements of different protective effect levels of masks are shown in Table 4.


Table 4 Requirements for the protective effect of masks with different protective effect levels


Protection effect levelClass AClass BClass CClass D
Protection effect/% ≥90857565

5.5.2 When the protective effect level of the mask is A, the filtration efficiency should reach II and above; when the protective effect of the mask is B, C, and D, the filtration efficiency should reach III and above


Recommended equipment: Mask particle protection effect tester PFY-01 is used to test the protection effect of daily protective masks, medical masks and respirators against particles.

口罩颗粒物防护效果试验仪

Mask particle protection effect tester

 

8. Color fastness to rubbing test items


GB/T 32610 Daily protective mask


Refer to the method standard GB 29865, the color fastness requirement is ≥4.


Recommended equipment: public test MCY-02 mask color fastness tester



9. Surface moisture resistance test items

GB19083 Medical protective mask

4.8 Surface moisture resistance


The water level of the mask should not be lower than the GB3 level in GB/T4745



Mask testing instrument manufacturer


Jinan Zhongce Electromechanical Equipment Co., Ltd. is a high-tech enterprise dedicated to the research and development and production of mask testing instruments. The company has a group of professionals who have been in the packaging testing field for 10 years, with rich testing experience and strong technical force. Can provide you with professional personalized customization and systematic solutions, please call for consultation!

scan it

Follow WeChat public account

Product Center

Jinan Zhongce Electromechanical Equipment Co., Ltd.

Consulting Hotline: 053188983898/18660817670

Email: sales@pubtester.com

Address: Times Headquarters Base, Tianqiao District, Jinan City, Shandong Province



  • Telephone

    • 15953109609
Technical Support: 全企网 | Admin Login