DVT-01 Catheter Vacuum Leak Tester is designed in accordance with Annex D of EN1618 for resistance to leakage during aspiration or vacuum. It also complies with the negative pressure test requirement of infusion sets. DVT-01 is suitable to the determination of negative pressure leakage test of infusion set, blood transfusion set, infusion needle, anesthesia bag filter, tubing, catheter, quick connector, etc.
DVT-01 Catheter Vacuum Leak Tester is designed in accordance with Annex D of EN1618 for resistance to leakage during aspiration or vacuum. It also complies with the negative pressure test requirement of infusion sets. DVT-01 is suitable to the determination of negative pressure leakage test of infusion set, blood transfusion set, infusion needle, anesthesia bag filter, tubing, catheter, quick connector, etc.
DVT-01 Catheter Vacuum Leak Tester
Product Features
-0~ -90Kpa wide negative pressure test range for various catheters
-Equipped with vacuum transition tank to prevent water from backing up into the equipment
-High-speed and high-precision sampling chip to ensure test accuracy and effectiveness
-Automatic constant pressure air supplement to ensure that the test can be carried out under preset vacuum conditions
-Automatic blowback and unloading function, making the end of the test process simple and smooth
-Safety design such as over-voltage safety protection and power-down memory ensure the stability of the system during the test
-Equipped with standard RS232 interface, which is convenient to PC connection and data transmission
Originality design
-7” HD LCD, displaying test data in real time
-Gradient test mode easy to find out the critical value of specimen leakage pressure
-Vacuum degree and time can be preset, input the value can enter the test mode
-With a powerful data storage function, which can store up to 50,000 test records
-The result is automatically determined, and the test data can be printed
-Multi-level user rights management, password login
Technical Specifications
Specifications | DVT-01 |
Test Range | 0 ~ -90kPa |
Accuracy | 0.1%FS |
Vacuum Maintain Performance | Automatic pressure maintain |
Test Time | 0~99999s (Setting freely) |
Test Error | ≤ ± 1 |
Power Supply | 220V, 50Hz |
Net Weight | 20Kg |
Applications
Basic Application | Extended Application |
Non-intravascular catheters | Infusion set, Blood transfusion set |
Standards
EN1618, GB 15812.1, GB8368, YY0489
Configuration
Standard Configuration: Instrument, micro printer, touch screen