Current Location: Home> Testing Instruments> Testing Instruments> Medical Device Testing Instruments> Catheter Residual Vacuum Tester
Catheter Residual Vacuum Tester

DVT-02 Catheter Residual Vacuum Tester is suitable to the determination of negative pressure leakage test of infusion set, blood transfusion set, infusion needle, anesthesia bag filter, tubing, catheter, quick connector, etc.



Contact Us
A3-2, Yinfeng International Biological City, Hi-tech East Zone, Jinan 250104, Shandong, China
+86-531-88983898/88983889
Sales01@pubtestercn.com, Sales02@pubtestercn.com
Product overview

DVT-02 Catheter Residual Vacuum Tester is suitable to the determination of negative pressure leakage test of infusion set, blood transfusion set, infusion needle, anesthesia bag filter, tubing, catheter, quick connector, etc.


Catheter Residual Vacuum Tester

Catheter Residual Vacuum Tester



Product Features

-Consists of an exhalation gas source (positive pressure gas source) that can be adjusted for flow, a standard prescribed exhalation gas piping system, etc. Special gas circuit conversion components are used to ensure that the exhalation gas piping system can be replaced easily and quickly

-With built-in flow control, integrated testing, no external accessories required

-Equipped with pressure sensors for higher accuracy

-High-speed and high-precision sampling chip to ensure test accuracy and effectiveness

-Safety design such as over-voltage safety protection and power-down memory ensure the stability of the system during the test

-Equipped with standard RS232 interface, which is convenient to PC connection and data transmission

Originality design

-7" HD LCD, displaying test data in real time

-With a powerful data storage function, which can store up to 50,000 test records

-The result is automatically determined, and the test data can be printed

-Historical data can be viewed and printed quickly

-Multi-level user rights management, password login 


Technical Specifications


Specifications

DVT-02

Flow Rate

30L/min

Flow Accuracy

± 5%

Pressure

10Kpa

Resolution

0.01Kpa

Pressure Accuracy

1% FS

Power Supply

220V, 50Hz

Net Weight

30Kg


Applications

Basic Application

Suction catheters


Standards

ISO8836, YY0339


Configuration

Standard Configuration: Instrument, micro printer, touch screen


Testing Instruments
Testing Instruments
Test Property
Test Material
Laboratory
Laboratory
Test Item
Test Material
Consulting
News
Company News
Industry News
Cases
Services
Solutions
Service
About Us
Introduction
Office
Certification
Customers
Contact Us
Sales01@pubtestercn.com, Sales02@pubtestercn.com
A3-2, Yinfeng International Biological City, Hi-tech East Zone, Jinan 250104, Shandong, China
Copyright © Pubtester Instruments Co., Ltd. All Right Reserved